# Runbook: Open Dental — Duplex ADF scanner captures only one side
|
||
|
||
**Applies to:** Any single-pass duplex ADF scanner feeding Open Dental over **TWAIN** on a Windows 11 workstation (standalone / self-enrolled is common). Written against a Canon imageFORMULA DR-series with the combined ISIS/TWAIN/WIA driver package, but the diagnostic tree is model-agnostic.
|
||
**Symptom:** A double-sided document run through the ADF into the Open Dental **Imaging** module lands as front-only — the back side is missing, blank, or pages come out in the wrong order.
|
||
**Most likely cause:** Duplex is not enabled on whichever setting is *authoritative*, and which one is authoritative depends on the **Show TWAIN UI** toggle. The classic miss is a checked-but-inert control on the branch that isn't in charge.
|
||
|
||
**Placeholders:**
|
||
|
||
| Placeholder | Meaning |
|
||
|---|---|
|
||
| `<WORKSTATION>` | The Windows 11 workstation with the scanner attached |
|
||
| `<SCANNER_MODEL>` | The duplex ADF scanner model (e.g. a Canon DR-series) |
|
||
| `<TWAIN_SOURCE>` | The native TWAIN data source name as it appears in Open Dental's **Twain Name** dropdown |
|
||
| `<TEST_PATIENT>` | A dummy patient/chart used for test scans only — never a live chart |
|
||
| `<OD_USER>` | The Open Dental user the front desk actually scans as |
|
||
|
||
---
|
||
|
||
## Key concept — where duplex is governed
|
||
|
||
> [!IMPORTANT]
|
||
> In Open Dental, duplex is controlled in **one of two places**, and only one is live at a time. The **Show TWAIN UI** toggle (Setup → Imaging → **Edit Imaging Device**) decides which:
|
||
>
|
||
> - **Show TWAIN UI = OFF** → **Open Dental's own Duplex checkbox** (Imaging Quality → **Multipage Scans**) is authoritative. The scanner's own dialog never appears.
|
||
> - **Show TWAIN UI = ON** → the **scanner's TWAIN dialog at scan time** is authoritative. Open Dental's Duplex checkbox is **inert** — it is not read.
|
||
>
|
||
> **The trap:** an OD Duplex checkbox that is checked *while Show TWAIN UI is ON* (or a scanner dialog set to duplex *while Show TWAIN UI is OFF*) changes nothing. A control set correctly on the **wrong branch** is the single most common misdiagnosis here. Always establish the toggle state **first**, then set duplex on the branch that matches it.
|
||
|
||
---
|
||
|
||
## Diagnostic steps
|
||
|
||
Work these in order. Steps a–c establish ground truth before you change anything.
|
||
|
||
### a. Confirm the Twain Name binds to the NATIVE source, not a WIA bridge
|
||
|
||
In **Edit Imaging Device**, check the **Twain Name** value.
|
||
|
||
- It should be the vendor's **native TWAIN** source (e.g. the `<SCANNER_MODEL>` TWAIN entry).
|
||
- If it reads **`WIA-<SCANNER_MODEL>`** or any `WIA-…` entry, that is the Windows WIA→TWAIN bridge. **The WIA bridge frequently drops the second side** and cannot be relied on for duplex. Re-select the native TWAIN source.
|
||
|
||
If the native source isn't in the list, the 32-bit TWAIN driver isn't registered — see [Gotchas](#gotchas).
|
||
|
||
### b. Record the Show TWAIN UI state
|
||
|
||
Note whether **Show TWAIN UI** is **ON** or **OFF**. This determines which fix branch applies below. Write it down — you'll restore or deliberately set it.
|
||
|
||
### c. Screenshot the current settings (baseline / rollback)
|
||
|
||
Capture the current **Edit Imaging Device** and **Imaging Quality → Multipage Scans** settings before touching anything, so you have a known-good rollback point and a record of what changed.
|
||
|
||
> [!WARNING]
|
||
> Screenshots for your own rollback are fine, but they may contain client-identifying detail (hostname, user, chart data). Keep them in the **private tier** — never attach them to this public repo.
|
||
|
||
### d. Confirm the scan action is multi-page (ADF), not single-page
|
||
|
||
The front-desk action must be **Scan Multi-Page Document** (ADF → multi-page PDF). The plain **Scan Document** action pulls a single page and **can never be duplex** regardless of every other setting. If the button in use is single-page, that alone explains front-only output.
|
||
|
||
### e. Reproduce with a real double-sided document
|
||
|
||
Feed a genuine two-sided document through the ADF and record the **exact** failure mode — they point at different causes:
|
||
|
||
| Observed | Points toward |
|
||
|---|---|
|
||
| Front pages only, backs never appear | Duplex off on the authoritative branch (step f) |
|
||
| Backs captured then dropped if blank/light | **Skip Blank Page** is on (see Gotchas) |
|
||
| Both sides present but interleaved/out of order | Scan-order / driver page-order setting |
|
||
|
||
### f. Apply the fix for the matching branch
|
||
|
||
Use the [decision table](#fix-decision-table) below, keyed to the Show TWAIN UI state from step b.
|
||
|
||
### g. If still failing, isolate with Twacker over TWAIN
|
||
|
||
Twacker is the reference TWAIN test application. Scan the same document through Twacker against the **same `<TWAIN_SOURCE>`**:
|
||
|
||
- **Works in Twacker, fails in Open Dental** → the driver and hardware are fine; the problem is Open Dental configuration or how it drives the source. Return to steps a–f.
|
||
- **Fails in Twacker too** → the problem is below Open Dental: driver settings or hardware. Fix it in the scanner's TWAIN dialog / driver, then retest.
|
||
|
||
### h. Verify end-to-end and set as default
|
||
|
||
1. Trigger the scan from the **actual front-desk button** as `<OD_USER>` — not a settings-screen test.
|
||
2. **Open the resulting PDF** and confirm **both sides are present and in reading order**.
|
||
3. Set the working configuration as the **default** so it survives an app restart or profile reset. A fix that only holds for the current session isn't done.
|
||
|
||
---
|
||
|
||
## Fix decision table
|
||
|
||
| Show TWAIN UI | Authoritative setting | Action |
|
||
|---|---|---|
|
||
| **OFF** | Open Dental **Duplex** checkbox (Imaging Quality → Multipage Scans) | **Check it.** |
|
||
| **ON** | Scanner's **TWAIN dialog** at scan time | Set **Scanning Side = Duplex**; set **Skip Blank Page = OFF**. |
|
||
|
||
> **Resolved example (OFF branch):** In the case that prompted this runbook, **Show TWAIN UI was OFF** and Open Dental's **Duplex** checkbox was **unchecked**. Checking it resolved the issue immediately — no driver or hardware change needed. This is the common OFF-branch outcome; still walk the tree above rather than assuming, since the ON branch fails differently.
|
||
|
||
---
|
||
|
||
## Gotchas
|
||
|
||
- **"Skip Blank Page" masquerades as simplex.** With this enabled in the TWAIN driver, a blank or light back side is **silently deleted on save** — the output looks exactly like a simplex scan even though both sides were captured. Turn it **OFF** while diagnosing duplex.
|
||
- **Open Dental is 32-bit and binds a 32-bit TWAIN source.** Open Dental only supports **32-bit TWAIN** drivers. The ISIS/TWAIN/WIA package installs a 32-bit source, and Open Dental (a 32-bit app) binds to it. A 64-bit-only driver, or picking the wrong source, means no working duplex — confirm the **native 32-bit TWAIN** source is what's selected in step a.
|
||
- **Windows Fax and Scan is NOT a valid isolation test.** It drives the scanner over **WIA, not TWAIN**. It can succeed while the TWAIN path fails (or vice versa) and tells you nothing about an Open Dental/TWAIN problem. Use **Twacker over TWAIN** (step g) for isolation.
|
||
- **Mechanical checks.** Before chasing software: the feed/separation **lever is in the separation (multi-sheet) position**, **double-feed detection** isn't misfiring and halting the second side, and the back side of the test document **genuinely has content**.
|
||
|
||
---
|
||
|
||
## Compliance note
|
||
|
||
> [!WARNING]
|
||
> Run all test scans into a **`<TEST_PATIENT>`** dummy account — **never a live chart**. When finished, **purge the test images** from `<TEST_PATIENT>` so no stray PHI or test scans are left behind. Confirm the dummy account holds nothing before leaving the workstation.
|
||
|
||
## References
|
||
|
||
- Open Dental manual — Imaging module / device setup: <https://www.opendental.com/manual/imaging.html>
|
||
- Open Dental manual — Edit Imaging Device (Twain Name, Show TWAIN UI): <https://www.opendental.com/manual/imagingdevices.html>
|